- Tube Furnace, Program Control
• Use for heating a sample at a high temperature by forming a gas atmosphere
• Program control
- Store several steps of increasing temperature and maintaining times and choose it to run
- Available precise controlling and inhibiting temperature overshoot
- Available to set 2 patterns / 18 segment
• Convenient for tube installation by retractable between upper and lower parts
• Auto tuning, and temperature calibration available
• Installed port for RS485 for PC communication
• LK Labkorea
Cat. No | Model | Tube Size | Heat Zone |
---|---|---|---|
F08-02-280 | LF-GT630 | Ø 60mm | 300 mm |
F08-02-285 | LF-GT660 | 600 mm | |
F08-02-290 | LF-GT1030 | Ø 100mm | 300 mm |
F08-02-295 | LF-GT1060 | 600 mm |
Cat. No. | F08-02-280 | F08-02-285 | F08-02-290 | F08-02-295 | |
---|---|---|---|---|---|
Model | LF-GT630 | LF-GT660 | LF-GT1030 | LF-GT1060 | |
Heat Zone | 300 mm | 600 mm | 300 mm | 600 mm | |
Tube Size | Ø60mm | Ø100mm | |||
Controller | Control | Program Control | |||
Display | GLCD (Graphic LCD) | ||||
Program | 2 Pattern 18 Segment | ||||
Temperature | Max. 1000℃ | ||||
External Dimension (mm) | w400×d400×h580 | w700×d400×h580 | w400×d440×h620 | w700×d440×h620 | |
Material | Internal | Ceramic Fiber Board | |||
External | Powder Coated Steel | ||||
Electric Supply | Power | 1 Phase, 220 VAC, 50/60 Hz | |||
Max Consumption | 1.8 kW (8.2 A) | 2.5 kW (11.4 A) | 2.2 kW (10 A) | 3.2 kW (14.7 A) | |
Power Line | Standard Plug | ||||
Safety | Over Temp. & Current Protection, Automatical Fault Sensing System |
Cat. No | Model | 재질 | Size, od x L |
---|---|---|---|
T16-45-228 | AT-060 | Alumina | ф60 × L1000mm |
T16-45-270 | AT-100 | ф100 × L1000mm | |
Q01-60-288 | QTS1048 | Quartz | ф60 × L1200mm |
Q01-60-312 | QTS1052 | ф100 × L1200mm |
- • Please contact us if you need other sizes
Cat. No | Model | 사용 Tube Size |
---|---|---|
F08-02-810 | TFGM060 | for ф60mm Tube |
F08-02-825 | TFGM100 | for ф100mm Tube |
-
• Install it on both sides of the tube to seal the internal of the tube
• Gas can be injected into the tube via the gas injection port to create a gas atmosphere
• The vacuum pump removes internal air to create a vacuum atmosphere
• LF-GT660 and LF-GT1060 models require coolant circulation for gas mask protection when running at high temperature
• Gas filling port : 1/4 tubing lock, coolant filling port: 1/8 hose nipple
Cat. No | Model | 사용 Tube Size | 적용 Model |
---|---|---|---|
F08-02-878 | TFBK060 | for ф60mm | LF-GT6XX |
F08-02-888 | TFBK100 | for ф100mm | LF-GT10XX |
- • Avoid sagging both ends of the tube due to the weight of the gas mask during a high-temperature drive