- Fume Hood
• Use for experiments where discharging of harmful gases occur
• Installed valve for water, gas, and air
• Available to add one extra valve among vacuum, gas, and air valve (option)
• Installed drainage of PVC material
• Installed 4 units 220V of rain proof type outlet (110V outlet available upon request)
• Available to add Internal blower on request (option)
• Door limit function: prevent to expose the harmful substances due to unexpected door position changes
by stopping the hood door at the appropriate height
• Safety bumps on a working plate: preventing the spilled solvent from flowing to the outside
• Face velocity controller available (option)
- Constantly controlling the Inhaled wind speed when the door opening height changes
- Alarm occurs when wind speed drops below a reference value
• LK Labkorea
Cat. No | Model | External Wide | 하부타입 |
---|---|---|---|
H02-26-030 | FHB-1200 | 1200 mm | 프레임형 |
H02-26-060 | FHB-1500 | 1500 mm | |
H02-26-080 | FHB-1800 | 1800 mm | |
H02-26-035 | FHD-1200 | 1200 mm | 캐비넷형 |
H02-26-065 | FHD-1500 | 1500 mm | |
H02-26-085 | FHD-1800 | 1800 mm |
Cat. No. | H02-26-030 / H02-26-035 | H02-26-060 /H02-26-065 | H02-26-080 / H02-26-085 | |
---|---|---|---|---|
Model | FHB-1200 / FHD-1200 | FHB-1500 / FHD-1500 | FHB-1800 / FHD-1800 | |
Material | Internal /External | Phenol Plate | Working Plate | Phenol Plate 25T |
Frame | Power Coated Aluminum | |||
Door | Tempered Glass | |||
Size | Internal | w981×d642×h1143mm | w1281×d642×h1143mm | w1581×h642×d1143mm |
External, Normal / Max | w1200×d815×h2357 / h2557mm | w1500×d815×h2357 / h2557mm | w1800×d815×h2357 / h2557mm | |
Power Outlet | 220V × 4ea | |||
Valve | Gas, Air, Water each 1 PC | |||
Lamp | LED × 1ea | LED × 2ea | ||
Exhausted Volume(Door Full Open) | 1100 cmh | 1400 cmh | 1700 cmh | |
Exhausted Hole Φ (mm) | ø250 mm | |||
Power | 1 Phase, 220Vac, 60Hz | |||
Door Open Height |
Limit | 500 mm | ||
Max. | 800 mm |
Cat. No. | Model | Description |
---|---|---|
H02-26-930 | FH-CA600 | 600mm Exhaust Cabinet |
H02-26-935 | FH-CA900 | 900mm Exhaust Cabinet |
- • Remove fumes from the stored specimen through a pipe on the rare of the cabinet connected to the fume hood exhaust
• Available to install only frame type
• Up to two can be used in combination depending on fume hood size
Example) 1500mm Hood : FH-CA600 + FH-CA900
Cat. No. | Model | Description |
---|---|---|
H02-26-950 | FH-VAV | Face Velocity Controller |
H02-26-955 | FH-ALM | Face Velocity Monitor Only |
-
• Constantly controlling the Inhaled wind speed when the door opening height changes
• Alarm occurs when wind speed drops below a reference value
Cat. No. | Model | Pipe | Connector | Description |
---|---|---|---|---|
H02-26-940 | FH-SF12 | 950 mm 2ea(x-axis) 750 mm 3ea(y-axis) 140 mm 6ea(z-axis) |
6ea | For 1200 Support Frame |
H02-26-942 | FH-SF15 | 1250 mm 2ea(x-axis) 750 mm 4ea(y-axis) 140 mm 8ea(z-axis) |
8ea | For 1500 Support Frame |
H02-26-944 | FH-SF18 | 1550 mm 2ea(x-axis) 750 mm 5ea(y-axis) 140 mm 10ea(z-axis) |
10ea | For 1800 Support Frame |
- • Available to install support frame to hang the laboratory equipment on the inside of Hume Hood
• Easy to install by screw type holder and excellent corrosion resistant by PP material
• Stainless Steel Rod and connection clamp set
Cat. No. | Model | Description |
---|---|---|
H02-26-960 | FH-AIRV | Air Valve Add |
H02-26-963 | FH-GASV | Gas Valve Add |
H02-26-966 | FH-VACV | Vacuum Valve Add |
H02-26-825 | FH-IF200 | Internal Blower, ø250 (220V / 60Hz / 50W) |